Home         Authors   Papers   Year of conference   Themes   Organizations        To MES conference

Accurate High-speed Frequency Meter for Doppler Initial Velocity Measurement  

Authors
 Liventsev E.V.
 Pereverzev A.L.
 Primakov E.V.
 Ryzhkova D.V.
 Silantiev A.M.
Date of publication
 2018
DOI
 10.31114/2078-7707-2018-2-156-161

Abstract
 The article considers the issue of high-speed frequency measurement of low-frequency signal for initial velocity estimation in Doppler velocity meter. Authors reviewed existing frequency measurement techniques and proposed another measurement method with a structure of the hardware frequency meter block for a system on FPGA controlling Doppler meter. The article gives a measurement error calculation for proposed method and analysis of developed structure characteristics on real signal.
Keywords
 frequency meter, control system, FPGA.
Library reference
 Liventsev E.V., Pereverzev A.L., Primakov E.V., Ryzhkova D.V., Silantiev A.M. Accurate High-speed Frequency Meter for Doppler Initial Velocity Measurement // Problems of Perspective Micro- and Nanoelectronic Systems Development - 2018. Issue 2. P. 156-161. doi:10.31114/2078-7707-2018-2-156-161
URL of paper
 http://www.mes-conference.ru/data/year2018/pdf/D101.pdf

Copyright © 2009-2024 IPPM RAS. All Rights Reserved.

Design of site: IPPM RAS